| Silo Discharge B7. 4 Outlet Air Distributor |
||||||||||
INGESOA®4 Outlet Air Distributos can be employed to sequentially distribute fluidizing air in storage silos and in blending systems.
These units are provided with two air inlets, one for ACTIVE air, which directs the air flow to an outlet, and the other one for INACTIVE air, which distributes the air flow to the three remaining outlets. When storage silo discharge is needed, the full volume of air is introduced through the ACTIVE air supply source. In this case the air flow is directed in sequence into each quadrant while the other three remain non-aerated. When the distributor is used to homogenize materials the ACTIVE air is directed into the blending quadrant, while the INACTIVE air travels through the three aeration quadrants. The volume of blending air is considerably higher (75% of the total) than the volume of aeration air (25%). Each quadrant acts in sequence as the blending quadrant, while the other three serve as aeration quadrants. INGESOA®4 Outlet Air Distributors are very reliable and of great simplicity, recommended when more complex solutions are not needed. Actuator available: motorized. |
||||||||||
|
![]() ![]() |
|||||||||